First checks
- Is the unit powered and is the circuit breaker on?
- Is the timer or schedule locking out heating during peak hours?
- Has demand simply exceeded the cylinder — a full guest house on one 200L cylinder will run out regardless of the plant.
Mechanical faults
- Iced evaporator on cold Gauteng mornings, usually a defrost or airflow issue.
- Failed circulation pump — the plant runs but water does not move through the heat exchanger.
- Sensor or controller fault — incorrect temperature readings stop the cycle early.
- Refrigerant loss — capacity falls off and run times climb.
- Scale build-up in hard-water areas, which insulates the heat exchanger.
Maintenance that prevents most of this
An annual service — coil clean, pump check, sensor verification and cylinder inspection — is far cheaper than an out-of-season failure.